logo

商品の詳細

Created with Pixso. ホーム Created with Pixso. 製品 Created with Pixso.
環境試験の部屋
Created with Pixso.

Programmable Constant Temperature & Humidity Test Chamber | -40℃ to +150℃ Environmental Chamber

Programmable Constant Temperature & Humidity Test Chamber | -40℃ to +150℃ Environmental Chamber

ブランド名: Sinuo
モデル番号: SN881C-3240L
MOQ: 1
価格: Customized
支払条件: T/T
供給能力: 毎月10セット
詳細情報
起源の場所:
中国
証明:
Calibration Certificate (Cost Additional)
温度範囲:
-40℃ → +150℃
湿度範囲:
(20~98)%RH
加熱速度:
≥2~3℃/min (平均、無負荷)
冷却速度:
≥1℃/min (平均、無負荷)
負荷状態:
鉄荷重50kg
わずかな内部容積:
3240L
パッケージの詳細:
合板
供給の能力:
毎月10セット
ハイライト:

Programmable humidity test chamber

,

Environmental chamber -40℃ to +150℃

,

Constant temperature test chamber

製品説明
Programmable Constant Temperature & Humidity Test Chamber | -40℃ to +150℃ Environmental Chamber

Product information:

The programmable constant temperature and humidity test chamber is designed to simulate various environmental conditions for reliability testing of products.

It can precisely control temperature and humidity, performing high-temperature, low-temperature, damp-heat, and cyclic environmental tests in line with international standards. Widely used in electronics, automotive, and material industries, it helps verify product performance and stability under different climatic conditions.

The chamber features a 7-inch touchscreen controller, safety protection mechanisms, and a durable stainless steel interior for long-term, reliable operation.

Programmable Constant Temperature & Humidity Test Chamber | -40℃ to +150℃ Environmental Chamber 0

Sample restrictions:

Operations forbidden on this test equipment:

• Testing or storage of samples containing flammable, explosive or highly volatile substances

• Testing or storage of corrosive samples

• Testing or storage of biological samples

• Testing or storage of samples with strong electromagnetic emission sources

Programmable Constant Temperature & Humidity Test Chamber | -40℃ to +150℃ Environmental Chamber 1

Equipment technical parameters:
Volume, Dimensions and Dimensions
Nominal Internal Volume 3240L
Internal Chamber Dimensions W1500 × H1800 × D1200 mm
External Dimensions W1750 × H2350 × D2500 mm
Weight Approx. 1050 kg
Performance

Test Environmental Conditions





Test Methods

Under the conditions of ambient temperature +25℃, relative humidity ≤85%, and no test sample inside the chamber.

GB/T 5170.2-1996 Temperature test equipment

GB/T2423.2-2008 (IEC60068-2-2:2007) Environmental testing – Test Bb: Dry heat

GJB150.3-1986 High temperature test

GB/T2423.1-2008 (IEC60068-2-1:2007) Environmental testing – Test Ab: Cold

GJB150.4-1986 Low temperature test

GJB150.9-1986 Thermal test

GB/T2423.3-2006 (IEC60068-2-78:2007) Environmental testing – Test Cab: Damp heat, steady state

GB/T2423.4-2008 (IEC60068-2-30:2005) Environmental testing – Test Db: Damp heat, cyclic

Temperature Range -40℃ → +150℃




Humidity Range

(20 ~98) %RH (At a temperature of 20℃ to 85℃, refer to the temperature and humidity control range diagram, no active heat load)
Programmable Constant Temperature & Humidity Test Chamber | -40℃ to +150℃ Environmental Chamber 2
Temperature Fluctuation ±0.5℃
Humidity Fluctuation ≤2.5% RH
Temperature Deviation ≤±2.0℃
Humidity Deviation ≤±3% RH
Heating Rate ≥2~3℃/min (average, no-load)
Cooling Rate ≥1℃/min (average, no-load)
Load Condition 50 kg iron load
Operating Noise A-weighted sound level ≤70 dB(A) (Measured in a quiet room at an ambient temperature of 25℃ using A-weighting, as the average of measurements taken at 9 points; each test point is 1 meter horizontally from the noise source and 1 meter above the ground.)






Compliant Test Standards

GB 11158 High-temperature test chamber technical specifications

GB 10589-89 Low-temperature test chamber technical specifications

GB 10592-89 High and low temperature test chamber technical specifications

GB/T 10586-89 Humidity-heat test chamber technical specifications

GB/T 2423.1-2008 Environmental testing – Test Ab: Cold

GB/T 2423.2-2008 Environmental testing – Test Bb: Dry heat

GB/T 2423.3-2006 Environmental testing – Test Cab: Damp heat, steady state

GB/T 2423.22-2002 Environmental testing – Test N: Change of temperature

IEC 60068-2-1:1990 Environmental testing – Part 2-1: Tests – Test A: Cold

IEC 60068-2-2:1974 Environmental testing – Part 2-2: Tests – Test B: Dry heat

Refrigeration System
Operating Mode Air-cooled mechanical compression single-stage refrigeration system


Refrigeration Unit

1.US Copeland low-temperature, low-noise scroll compressor (air-cooled heat dissipation)

2.Cooling method: Air-cooled

Heat Exchanger

Cascade refrigeration system with imported US Copeland low-temperature, low-noise scroll compressor. Adopts high-efficiency SWEP refrigerant heat exchanger (Sweden-made, SUS #316), with higher efficiency than traditional internal spiral designs.


Heat Load Regulation

1.Adopts automatic refrigerant flow control device to effectively remove the heat load from the test sample, keeping pace with German/Japanese technology

2.Compared with traditional designs, it provides higher control stability and repeatability, while achieving superior energy efficiency and power savings.

Refrigeration Compressor US Copeland low-temperature, low-noise scroll compressor


High-Efficiency Components

1.Condenser and evaporator use AC&R multi-pass turbulence-type aluminum fin devices.

2.Throttling devices all use imported well-known refrigeration accessories.

Expansion System Capacity-controlled refrigeration system
Evaporative Condenser All-copper tube heat exchanger



Refrigeration Control Method

1.The controller automatically adjusts the operating conditions of the refrigeration compressor according to test conditions, controlling the cooling capacity output to achieve power and water savings. Operating conditions are more stable, with a 30% power saving in humidity operation.

2.Evaporating pressure regulating valve

3.Compressor suction gas cooling circuit

Electrical Control System

a) Controller Model

Cold-balance touch-screen intelligent programmable temperature controller (with energy-saving control function)










b) Controller Specifications

Technical Specifications:

1.7-inch true-color touchscreen display

2.Two control modes: Program / Fixed value

3.Sensor type: 2-channel PT100 input (electronic sensor input optional)

4.Output modes: Voltage pulse (SSR) / Control outputs: 2 channels (Temperature / Humidity) / 2 channels 4–20mA analog output / 16 relay outputs (passive)

5.Control signals: 8 IS control signals / 8 T control signals / 4 AL control signals

6.Alarm signals: 16 DI external fault alarms

7.Temperature measurement range: -90.00℃ ~ 200.00℃ (optional -90.00℃ ~ 300.00℃), accuracy ±0.2℃

8.Humidity measurement range: 1.0% ~ 100% RH, accuracy ±1% RH

9.Communication interface: (RS232/RS485, max communication distance 1.2km; up to 30km with optical fiber)

10.Interface languages: Chinese / English

11.With Chinese character input function

12.Printer support (USB function optional)

13.Multi-signal combined relay output, signals support logical operations (NOT, AND, OR, NOR, XOR), equivalent to PLC programming capability

14.Multiple relay control modes: Parameter→Relay mode, Relay→Parameter mode, logical combination mode, composite signal mode

15.Program editing: Up to 120 program groups, with a maximum of 100 segments per program




Controller Technical Parameters

• Accuracy: Temperature ±0.1℃ + 1 digit, Humidity ±1% RH + 1 digit

• Resolution: Temperature ±0.01℃, Humidity ±0.1% RH

• Temperature slope: 0.1 ~ 9.9 adjustable

• Upper/lower limit standby and alarm functions

• Input signals: Dry-bulb and wet-bulb PT100 × 2

• 9 sets of PID control parameters, with auto-tuning function

• Automatic dry/wet bulb calibration screen



Control Methods

1.Anti-integral windup PID control

2.BTC balance temperature control + DCC intelligent cooling capacity control + DEC intelligent electrical control (for temperature test equipment)

3.BTHC balance temperature and humidity control + DCC intelligent cooling capacity control + DEC intelligent electrical control (for temperature and humidity test equipment)







Display Functions

• Touchscreen dialog interface: No need for key input; directly touch options on the screen.

• Direct display of set value (SV) and process value (PV) for temperature.

• Displays currently executing program number, segment, remaining time, and cycle count.

• Operating cumulative time function.

• Graphical curve display of temperature program set values, with real-time program curve execution display.

• Dedicated program editing screen; minimum 5 segments of temperature/humidity and time can be entered per page.

• Free switching between Chinese and English languages.

• Fault prompt display screen.

• Adjustable screen backlight.

• Timed screen saver function (can be set by timer or manual shutdown).






Program Capacity & Control Functions

• Usable program groups: Max. 120 patterns.

• Usable memory capacity: Total 12,000 segments.

• Repeatable command execution: Each command up to 3,200 times.

• Dialog-style program editing with edit, clear, and insert functions.

• Segment time setting: 0 ~ 99 hours 59 minutes.

• 2 sets of programmable sequence control modules.

• Power-off program memory: Automatically resumes execution after power restoration.

• Equipped with RS-485 or RS-232 communication interface.

• Real-time graphical curve display during program execution.

• Automatic refrigeration capacity adjustment function.

• Scheduled start and shutdown functions.

• Date and time adjustment function.

• Key and screen lock (LOCK) function.